JSG · ENGINEERED PRODUCTS
JSG13G 3V Micro Diaphragm Gas Pump for Gas Sampling
Options to discuss with our team
- Voltage
- 3V DC
Compact 3V micro diaphragm gas pump for portable gas sampling, analytical instruments and OEM devices. The JSG13GE-KBD3 delivers 300 mL/min free flow in a 15 g body with a coreless brushed motor.
- Low-voltage design: 3V DC for compact portable equipment.
- Low-volume gas transfer: 300 mL/min atmospheric free flow.
- Pressure and vacuum functions: suction, exhaust and positive-pressure gas delivery.
- Compact integration: approx. 32.95 × 22.53 × 13.70 mm; 15 g.
- Standard gas-path materials: PA/PPS pump head with EPDM diaphragm and valves.
Pressure & Vacuum Operation
The JSG13GE-KBD3 supports both suction and positive-pressure operation. Maximum positive pressure is 35 kPa; maximum vacuum is -35 kPa. These are separate operating endpoints. Use the performance curve to check available flow at your required load.

Specifications
| Model | JSG13GE-KBD3 (JSG13G series) |
| Motor | Coreless brushed DC |
| Rated Voltage | 3V DC |
| Unloaded Current | 60 mA |
| Atmospheric Free Flow | 300 mL/min |
| Maximum Positive Pressure | 35 kPa |
| Maximum Vacuum | -35 kPa |
| Approx. Dimensions | 32.95 × 22.53 × 13.70 mm |
| Approx. Weight | 15 g |
| Motor Diameter | 12 mm |
| Ports | Barbed; approx. 3.60 mm OD / 1.10 mm bore |
| Pump Head | PA / PPS |
| Diaphragm / Valves | EPDM / EPDM |
| Media | Compatible gas |
| Ambient / Medium Temperature | 5–40°C |
| Noise (Published Value) | 55 dB; confirm test conditions for your application |
| Protection Rating | IP30 |

Check the complete drawing, tubing clearance, wiring and mounting arrangement before designing the enclosure.
Typical Applications
Portable gas samplers, handheld gas detectors, analytical instruments, air-quality monitors, sensor chambers, compact suction and exhaust modules, and OEM gas-handling systems.
Important Note
Free flow, maximum pressure and maximum vacuum are different operating points. Actual performance depends on tubing, filters, valves, system resistance, supply voltage and operating conditions. The 60 mA figure is unloaded current; confirm startup and loaded current when sizing the power supply.
For compatible gas only. Confirm gas composition, humidity, particles, condensation risk and material compatibility. Validate flow at the working point, duty cycle, temperature rise, noise and stability in the complete equipment before production approval.
Package Includes
1 × JSG13GE-KBD3 3V Micro Diaphragm Gas Pump
Tubing, filters, fittings, flowmeters, mounting accessories and power supply are not included unless agreed separately.
Technical Information
View Full Technical Specifications →
For samples, bulk orders or OEM configuration review, send your required flow at working pressure or vacuum, gas type, duty cycle, installation space and quantity to admin@dc-pump.com.